Skip to the content Skip to the navigation Accessibility information
Decagon Devices
Login|Register| Contact us
US: 1.800.755.2751
International: +1.509.332.2756
  • Home
  • Products
    • Water Activity
    • Environmental Instruments
    • Sensors
    • Data Loggers and Collectors
    • Environmental Monitoring Systems
    • Lysimeters and Infiltrometers
  • Services
    • Thermal Properties Testing
    • Soil Moisture Release Curve Construction
    • Campbell Scientific Data Logger Programming
    • Soil Moisture Sensor Custom Calibration
  • Support
  • News & Events
  • Where to Buy
  • About Us
    • About Us
    • Contact Us
    • Sister Companies
    • Employment
    • GA Harris Fellowship
    • People
  • Education
  • Forums
    • Soil Moisture
    • Data Loggers and Data Management
    • Canopy Measurements
    • Soil Water Potential
    • Lysimetry and Hydrology
    • Clarke Topp Twenty Questions
    • Best Practices of Soil Moisture Measurements Virtual Seminar Questions
    • Methods of Sampling and Analyzing Soil Pore Solution Virtual Seminar Questions
    • Basic Principles of Radiation Measurement to Predict ET, Climate Change, Photosynthesis and Crop Yield
    • Lysimetry Basics: Peering in to the Black Box Virtual Seminar Questions
Products
  • Water Activity
  • Environmental Instruments
  • Sensors
    • Soil Moisture Sensors
    • Ground Water Monitoring
      • CTD Sensor
    • Water Potential Sensors
    • Environmental Sensors
  • Data Loggers and Collectors
  • Environmental Monitoring Systems
  • Lysimeters and Infiltrometers
Request a
Quote
No Obligation
Subscribe to
newsletter
Tips, tricks, and Scholarships
Email to
a Friend
Send this page link to a friend

CTD Sensor

  • Overview
  • Specifications
  • Support
  • Education

The Decagon CTD sensor is a low cost, accurate tool for monitoring of water level, electrical conductivity, and temperature in both ground water and surface water.  The sensor utilizes a vented pressure transducer to obtain accurate water level measurements from 0 to 3.5 m, while removing the effects of barometric pressure.  With a range of 0 to 120 dS/m, the CTD sensor has the ability to make accurate electrical conductivity measurements in a broad range of applications.

Decagon's CTD sensor is a robust, marine grade sensor, 3.4 cm in diameter. It connects by cable to an external datalogger. Much of the complex circuitry is in the data logger, lowering the cost of individual sensors without impacting their accuracy or resolution.  This makes it so that instead having to rely on a single measurement, you can measure in several different locations without exceeding your budget.

The CTD sensor is compatible with all Decagon Em50 series and Campbell Scientific data loggers. The Em50G offers a remote transmission option to deliver data wirelessly to your desktop. With this option, water depth, temperature, and electrical conductivity can be monitored from any internet-connected computer in near-real time.

Applications

  • Aquifer recharge and recovery.
  • Saltwater intrusion, desalination, and wastewater.
  • Wetland monitoring. 
  • Groundwater contamination monitoring.
  • Surface water monitoring.

Advantages

  • Robust marine-grade epoxy overmold to resist corrosion in tough environments.
  • Compact 3.4 cm diameter sensor body to fit into tight spaces.
  • External logger with remote transmission option to deliver data to your desktop.
  • Permanent connection allows you to collect data continously without pulling up the sensor.
  • Low per-sensor cost.
CTD-Sensor-WEB.png CTD-Panels-WEB.png CTD in stream web CTD Catatlog Edit Pg 42
  • Get a quote for this product (United States)
  • Get a quote for this product (International)
  • Contact a Decagon sales representative

Specifications

Range: 

Water Depth: 0 to 3.5 m

Electrical Conductivity: 0 to 120 dS/m

Temperature: -40 to 50°C

Resolution:

Water Depth: 1 mm

Electrical Conductivity: 0.001 dS/m

Temperature: 0.1°C

Accuracy:

Water Depth: + 0.2 % of full scale @ 20 °C

Electrical Conductivity: + 0.01 dS/m or + 10 % (whichever is greater)

Temperature: + 1°C

Operating Temperature: 0 to 50°C (Pressure transducer cannot be allowed to freeze while submersed.)
Power Requirements: 3.6 - 15 VDC, 0.03 mA quiescent, 0.5 mA during 300 ms measurement
Dimensions: Housing: 3.4 cm Diameter, 9 cm length
Measurement Time: 300 ms (milliseconds)
Output: Serial TTL, 3.6 Volts Levels or SDI-12
Connector Types: 3.5 mm (stereo) plug, or stripped & tinned lead wires (3)
Cable Length: 10 m standard; custom lengths available upon request
Data Logger Compatibility (not exclusive)

Decagon: Em50 series

Campbell Scientific: Any logger with serial I/O including CR10X, CR23X, any CRBasic type logger;

Other: Any data acquisition system capable of 3.6 - 15V excitation, and serial or SDI-12 communication

Handheld Reader Compatibility:  ProCheck (rev 1.34+)
Software Compatibility: ECH2O Utility (rev 1.64+), DataTrac3 (rev 3.4+)

Support

Video

  • How Sensors Are Made
  • CTD Refill Video

Information Sheet

  • CTD Sensor Integrator's Guide for Serial and SDI-12 Communication

Manuals

  • Manual - CTD Sensor

Request Support

Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158

Education

Virtual Seminar

  • February 28, 2012: Virtual Seminar: Lysimetry Basics - Peering in to the Black Box

Sign up for News & Updates

Please fill out the information below

2365 NE Hopkins Court
Pullman, WA 99163 - USA
1-800-755-2751 / Int'l: 509-332-2756