Skip to the content Skip to the navigation Accessibility information
Decagon Devices
Login|Register| Contact us
US: 1.800.755.2751
International: +1.509.332.2756
  • Home
  • Products
    • Water Activity
    • Environmental Instruments
    • Sensors
    • Data Loggers and Collectors
    • Environmental Monitoring Systems
    • Lysimeters and Infiltrometers
  • Services
    • Thermal Properties Testing
    • Soil Moisture Release Curve Construction
    • Campbell Scientific Data Logger Programming
    • Soil Moisture Sensor Custom Calibration
  • Support
  • News & Events
  • Where to Buy
  • About Us
    • About Us
    • Contact Us
    • Sister Companies
    • Employment
    • GA Harris Fellowship
    • People
  • Education
  • Forums
    • Soil Moisture
    • Data Loggers and Data Management
    • Canopy Measurements
    • Soil Water Potential
    • Lysimetry and Hydrology
    • Clarke Topp Twenty Questions
    • Best Practices of Soil Moisture Measurements Virtual Seminar Questions
    • Methods of Sampling and Analyzing Soil Pore Solution Virtual Seminar Questions
    • Basic Principles of Radiation Measurement to Predict ET, Climate Change, Photosynthesis and Crop Yield
    • Lysimetry Basics: Peering in to the Black Box Virtual Seminar Questions
Products
  • Water Activity
  • Environmental Instruments
  • Sensors
  • Data Loggers and Collectors
    • Continuous Data Loggers
      • Em50 Digital/Analog Data Logger
      • Em50G Wireless Cellular Data Logger
      • Em50R Wireless Radio Data Logger
      • Em5b Analog Data Logger
    • Instantaneous Data Collectors
    • Data Management Software
  • Environmental Monitoring Systems
  • Lysimeters and Infiltrometers
Request a
Quote
No Obligation
Subscribe to
newsletter
Tips, tricks, and Scholarships
Email to
a Friend
Send this page link to a friend

Em50R Wireless Radio Data Logger

  • Applications:
    • Greenhouse Management,
    • Hydrology,
    • Wireless Sensor Networks
  • Overview
  • Specifications
  • Comparisons
  • Accessories
  • Support
  • Education

Download Data Without Visiting Your Logger

The Em50R lets you download data without plugging into your data logger as long as you are within radio range*.  The Em50R is a self-contained data logger built to power, read, log, and transmit data from five sensors. Logged data are transmitted via radio signal to a Decagon base station (DataStation or Rm-1).  All Decagon sensors work with the Em50R; no programming is necessary.

The Em50R has been used:

  • To monitor greenhouse fertigation from an office.
  • To collect data from 42 logger nodes in a soil moisture variation study.
  • To monitor multiple fields from a central support building.


Easy Connectivity Check

See signal strength and connection quality in real time as you pick the best spot for your data logger and antenna. This feature lets you test connectivity BEFORE you install the logger.

Safeguard Your Data

Occasionally, external factors can interfere with transmission. The Em50R has a "confirm data delivery" protocol to make sure that every data transfer is correct and complete. Transmitted data is also backed up in the data logger memory to give you an extra layer of data protection.

*The Em50R uses license-free radio technology to transmit data over intermediate distances, typically 1-3 miles. Range is decreased by buildings, trees, hills, and other obstacles between the data logger and the receiver. Range can be extended (up to 5 miles, or possibly greater depending on landscape features) with careful positioning and by using well-mounted high-gain antennas.

 

Em50R-Wireless-Radio-Logger.JPG Em50R-illustration.jpg
  • Get a quote for this product (United States)
  • Get a quote for this product (International)
  • Contact a Decagon sales representative

Specifications

Part number 40810

 

Radio Frequency 900 MHz, 2.4 GHz ISM (no license required)
Input channels 5 channels, each supporting 12-bit analog, 32-bit digital, or pulse, compatible with any Decagon Devices sensor
Data Storage 1 MB (36,000 scans of all 5 ports)
Sensor Types EC-5, 10HS, 5TM, 5TE, EC-TM, MPS-2, PAR, LWS, Temp, Temp/RH, precipitation, wind speed
Operating Environment -40 to 60°C, up to 100% RH
Power Requirements 5 AA alkaline or lithium batteries, (typically good for 8 - 12 months)
Case Dimensions 12.7 cm x 20.3 cm x 5.1 cm (5 in x 8 in x 2 in)
Case Material Weatherproof, UV- and impact-resistant IP55, NEMA 3R
Interface Cable Serial or USB (cable included)
Software Interface ECH2O Utility, ECH2O Utility Mobile, DataTrac
Warranty One year, parts and labor

Comparisons

Data LoggerPortsMemoryBatt. LifeCaseCompatibility w/SensorsWireless Options
Em5B 5 49 KB (18,000 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, 10HS, EC-10, EC-20, temperature, precipitation None
Em50 5 1 MB (36,000 scans) 1 - 3 years Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed, drain gauge None
Em50R 5 1 MB (36,000 scans) 6 months - 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed 900 MHz, 922 MHz, 2.4 GHz
em50g 5 1 MB (36,000 scans) 6 months - 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed GSM
Em5 (discontinued) 5 47 KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation None
Em5R (discontinued) 5 47 KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation 900 MHz

Accessories

DataStation-HERO1.jpg

DataStation

Collects data wirelessly from up to 80 data loggers within radio range (typically 1-3 miles). Stores 36,000 packets of data.

RM1-HERO1.jpg

Rm-1

The Rm-1 is a radio modem used for real-time connection to the Em50R data loggers. The RM-1 can also be used as a repeater in the wireless system. Use the Rm-1 with to change the logger name, logger date/time, sampling interval, and ports sensors assignments. You can also use it to download logged data all remotely from the convenience of your computer.

Support

Application Notes

  • DataTrac 3 Installation

Software & Downloads

  • DataTrac 3 Installation
  • Decagon USB Cable Adapter Driver (version 6.5)
  • ECH2O Utility (version 1.66)
  • Em50 Firmware Updater (version 2.12)

Manuals

  • Manual Em50/ Em50R/ Em50G

Request Support

Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158

Education

Virtual Seminar

  • November 9, 2010: Virtual Seminar: Strawberries: The Effects of Modifying Irrigation Methods for Transplant Establishment

Sign up for News & Updates

Please fill out the information below

Related Products or Services

  • Em50 Digital/Analog Data Logger
  • Em50G Wireless Cellular Data Logger
  • Em5b Analog Data Logger
2365 NE Hopkins Court
Pullman, WA 99163 - USA
1-800-755-2751 / Int'l: 509-332-2756
© 2013 Decagon Devices, Inc. - All Rights Reserved