You always want to know what's going on at your research site. But figuring out how to communicate with your data logger has typically been complicated and expensive. The Em50G lets you check in on your data logger from virtually anywhere in the world. The Em50G is a self-contained data logger built to power, read, and log data from five sensors. Logged data are transmitted from the logger to Decagon's server via internal cellular/mobile communication. All Decagon sensors work with the Em50G; no programming is necessary.
The Em50G uses an internal cell modem to automatically send data to an internet server four times a day. The stored data are available for you to access, monitor, and download at any time.
Decagon has over 120 cellualar/mobile GSM partners all over the world. To check and see if your site is covered, visit the GSM World Coverage Maps for the most up to date coverage information. If you're still not sure, you can demo an Em50G from Decagon and take it to your area to try out.
The Em50G powers, reads, and logs data from five sensors. All Decagon sensors work with the Em50G; no programming is necessary.
The Em50G takes about 20 minutes to set up. It comes complete with a data plan and is self-enclosed and self-powered. The logger case is rated NEMA 4X, IP45 for long-term outdoor use, and the logger will run (and power its sensors and the cell modem) for about six months on 5 AA batteries.
The Em50G has 5 sensor ports and one communication (download) port. Rather than having a screen and a keyboard, the Em50G is configured by plugging a laptop or handheld into the com port. ECH2O Utility software (included) provides setup windows where you set the logger clock, select the type of sensor on each port, and specify how often you want the sensors read.
See signal strength and connection speed in real time as you pick the best spot for the data logger. This feature lets you test connectivity BEFORE you install the logger.
Transmitted data is backed up in the data logger memory to give you an extra layer of data protection. A "confirm data transfer" protocol makes sure data transmission is correct and complete.
The Em50G stores about 36,000 data scans. A scan includes the date, time, and measurements from each of the five ports.
| Input Ports |
5, 12-bit analog or 32-bit digital, compatible with any Decagon Devices sensor |
|---|---|
| Port Type |
3.5mm "stereo jack" connector |
| Data Storage |
1MB (36,000 scans of all 5 ports) |
| Memory Type |
Non-Volatile Flash |
| Logging Interval |
5 minutes to 24 hours, logged data is 1-minute average of user-specified interval |
| Operating Environment | -30°C to 60°C, up to 100% RH |
| Battery Capacity |
5 AA alkaline or lithium batteries |
| Battery service life |
6+ months |
| External power needs |
None needed |
| Enclosure | Weatherproof, impact and UV-resistant polymer |
| Enclosure Dimensions |
12.7 x 20.3 x 5.1 cm (5 x 8 x 2 in) |
| Enclosure rating |
IP55, NEMA3R |
| Enclosure access |
Hinged door with eyelet for securing with user-supplied padlock |
| Mounting |
3.8cm (1.5 inch) mast or wall mount |
| Local Communication |
Dedicated serial port 3.5mm stereo jack for use with the Decagon Serial Cable Adapter (SCA) or Decagon USB Cable Adaptor (UCA) |
| Decagon Data Service (included with every Em50G) |
Data Plan: Annual, provided by Decagon Devices with 120 global partners, GSM service Server Location: Decagon Devices, Pullman, Washington Data Security: Web standard encrypted; a unique user id and password (provided with each logger) are necessary for accessing data from the server. |
| Transmit Frequency |
850/1900 MHz: 824-849 MHz, 1850-1910 MHz 900-1800 MHz: 890-915 MHz, 1710-1785 MHz |
| Data Logger | Ports | Memory | Batt. Life | Case | Compatibility w/Sensors | Wireless Options |
|---|---|---|---|---|---|---|
| Em5B | 5 | 49KB (18,000 scans) | Several months | Impact-resistant IP52, NEMA 3R | EC-5, 10HS, EC-10, EC-20, temperature, precipitation | None |
| Em50 | 5 | 1MB (36,000 scans) | 1-3 years | Weatherproof, UV- and impact-resistant IP55, NEMA 3R | EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed, drain gauge | None |
| Em50R | 5 | 1MB (36,000 scans) | 6 months- 1 year | Weatherproof, UV- and impact-resistant IP55, NEMA 3R | EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed | 900 MHz, 922 MHz, 2.4 GHz |
| em50g | 5 | 1MB (36,000 scans) | 6 months- 1 year | Weatherproof, UV- and impact-resistant IP55, NEMA 3R | EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed | GSM |
| Em5 (discontinued) | 5 | 47KB (3,400 scans) | Several months | Impact-resistant IP52, NEMA 3R | EC-5, EC-10, EC-20, temperature, precipitation | None |
| Em5R (discontinued) | 5 | 47KB (3,400 scans) | Several months | Impact-resistant IP52, NEMA 3R | EC-5, EC-10, EC-20, temperature, precipitation | 900 MHz |