Skip to the content Skip to the navigation Accessibility information
Decagon Devices
Login|Register| Contact us
US: 1.800.755.2751
International: +1.509.332.2756
  • Home
  • Products
    • Water Activity
    • Environmental Instruments
    • Sensors
    • Data Loggers and Collectors
    • Environmental Monitoring Systems
    • Lysimeters and Infiltrometers
  • Services
    • Thermal Properties Testing
    • Soil Moisture Release Curve Construction
    • Campbell Scientific Data Logger Programming
    • Soil Moisture Sensor Custom Calibration
  • Support
  • News & Events
  • Where to Buy
  • About Us
    • About Us
    • Contact Us
    • Sister Companies
    • Employment
    • GA Harris Fellowship
    • People
  • Education
  • Forums
    • Soil Moisture
    • Data Loggers and Data Management
    • Canopy Measurements
    • Soil Water Potential
    • Lysimetry and Hydrology
    • Clarke Topp Twenty Questions
    • Best Practices of Soil Moisture Measurements Virtual Seminar Questions
    • Methods of Sampling and Analyzing Soil Pore Solution Virtual Seminar Questions
    • Basic Principles of Radiation Measurement to Predict ET, Climate Change, Photosynthesis and Crop Yield
    • Lysimetry Basics: Peering in to the Black Box Virtual Seminar Questions
Products
  • Water Activity
  • Environmental Instruments
  • Sensors
  • Data Loggers and Collectors
    • Continuous Data Loggers
      • Em50 Digital/Analog Data Logger
      • Em50G Wireless Cellular Data Logger
      • Em50R Wireless Radio Data Logger
      • Em5b Analog Data Logger
    • Instantaneous Data Collectors
    • Data Management Software
  • Environmental Monitoring Systems
  • Lysimeters and Infiltrometers
Request a
Quote
No Obligation
Subscribe to
newsletter
Tips, tricks, and Scholarships
Email to
a Friend
Send this page link to a friend

Em50G Wireless Cellular Data Logger

  • Applications:
    • Greenhouse Management,
    • Hydrology,
    • Wireless Sensor Networks
  • Overview
  • Specifications
  • Comparisons
  • Support
  • Education
ou always want to know what's going on at your research site.  But figuring out how to communicate with your data logger is typically complicated and expensive.  The Em50G lets you check in on your data logger from virtually anywhere in the world.  The Em50G is a self-contained data logger built to power, read, and log data from five sensors. Logged data are transmitted from the logger to Decagon's server via internal cellular/mobile communication.  All Decagon sensors work with the Em50G; no programming is necessary.
Setting up the Em50G
Watch a two-minute video detailing the quick and easy Em50G set-up process
How it works
The standard Em50G uses an internal cell modem to automatically send data to an internet server four to six times a day (contact Decagon for more frequent data delivery options). The stored data are available for you to access, monitor, and download at any time.
Is my site in a coverage area?
Decagon has over 120 cellular/mobile GSM partners all over the world.  To check and see if your site is covered, contact Decagon or your local representative with your site's lattitude and longitude.  If you're still not sure, you can demo an Em50G from Decagon and take it to your site to double check.
Plug in Sensors, Start Logging Data
The Em50G powers, reads, and logs data from five sensors. All Decagon sensors work with the Em50G; no programming is necessary.
Ready to Go
The Em50G generally takes about 20 minutes to set up. It comes complete with a data plan, and is both self-enclosed and self-powered. The logger case is rated NEMA 4X, IP45 for long-term outdoor use, and the logger will run (and power its sensors and the cell modem) for about six months on 5 AA batteries.
Simple Setup
The Em50G has 5 sensor ports and one communication (download) port. Rather than having a screen and a keyboard, the Em50G is configured by plugging a laptop or handheld into its com port. ECH2O Utility software (included) provides setup windows which name the logger, set the logger clock, select the type of sensor on each port, and specify how often you want the sensors read.
Easy Connectivity Check
See signal strength and connection quality in real time as you pick the best spot for your data logger. This feature lets you test connectivity at your measurement site BEFORE you install the logger.
Data Safeguards
Transmitted data is backed up in the data logger memory to give you an extra layer of data protection. A "confirm data transfer" protocol makes sure data transmission is correct and complete.
Stores 36,000 Data Scans
The Em50G stores over 36,000 data scans. A scan includes the date, time, and measurements from each of the five ports.

Download Data Even From Remote Locations

You always want to know what's going on at your research site.  But figuring out how to communicate with your data logger is typically complicated and expensive.  The Em50G lets you check in on your data logger from virtually anywhere in the world.  The Em50G is a self-contained data logger built to power, read, and log data from five sensors. Logged data are transmitted from the logger to Decagon's server via internal cellular/mobile communication.  All Decagon sensors work with the Em50G; no programming is necessary.

Setting up the Em50G

Watch a two-minute video detailing the quick and easy Em50G set-up process

em50G video

How it works

The standard Em50G uses an internal cell modem to automatically send data to an internet server four to six times a day (contact Decagon for more frequent data delivery options). The stored data are available for you to access, monitor, and download at any time.

Is my site in a coverage area?

Decagon has over 120 cellular/mobile GSM partners all over the world.  To check and see if your site is covered, contact Decagon or your local representative with your site's lattitude and longitude.  If you're still not sure, you can demo an Em50G from Decagon and take it to your site to double check.

Plug in Sensors, Start Logging Data

The Em50G powers, reads, and logs data from five sensors. All Decagon sensors work with the Em50G; no programming is necessary.

Ready to Go

The Em50G generally takes about 20 minutes to set up. It comes complete with a data plan, and is both self-enclosed and self-powered. The logger case is rated NEMA 4X, IP45 for long-term outdoor use, and the logger will run (and power its sensors and the cell modem) for about six months on 5 AA batteries.

Simple Setup

The Em50G has 5 sensor ports and one communication (download) port. Rather than having a screen and a keyboard, the Em50G is configured by plugging a laptop or handheld into its com port. ECH2O Utility software (included) provides setup windows which name the logger, set the logger clock, select the type of sensor on each port, and specify how often you want the sensors read.

Easy Connectivity Check

See signal strength and connection quality in real time as you pick the best spot for your data logger. This feature lets you test connectivity at your measurement site BEFORE you install the logger.

Data Safeguards

Transmitted data is backed up in the data logger memory to give you an extra layer of data protection. A "confirm data transfer" protocol makes sure data transmission is correct and complete.

Stores 36,000 Data Scans

The Em50G stores over 36,000 data scans. A scan includes the date, time, and measurements from each of the five ports.

 

em50g-cutout1.jpg em50G-open.jpg Em50G-Data-Line.jpg
  • Get a quote for this product (United States)
  • Get a quote for this product (International)
  • Contact a Decagon sales representative

Specifications

Part number 40807

 

Input Ports
5 channels, each supporting 12-bit analog, 32-bit digital, or pulse, compatible with any Decagon Devices sensor
Port Type
3.5 mm "stereo jack" connector
Data Storage
1 MB (36,000 scans of all 5 ports)
Memory Type
Non-Volatile Flash
Logging Interval
5 minutes to 24 hours, logged data is 1-minute average of user-specified interval
DATA TRANSMISSION FREQUENCY Up to six times/day.  Contact Decagon for options for more frequent data delivery.
Operating Environment -30°C to 60°C, up to 100% RH
Battery Capacity
5 AA alkaline or lithium batteries
Battery service life
6+ months
External power needs
None needed
Enclosure Weatherproof, impact and UV-resistant polymer
Enclosure Dimensions
12.7 cm x 20.3 cm x 5.1 cm (5 in x 8 in x 2 in)
Enclosure rating
IP55, NEMA 3R
Enclosure access
Hinged door with eyelet for securing with user-supplied padlock
Mounting
3.8 cm (1.5 inch) mast or wall mount
Local Communication
Dedicated serial port 3.5 mm stereo jack for use with the Decagon Serial Cable Adapter (SCA) or Decagon USB Cable Adaptor (UCA)
Decagon Data Service (included with every Em50G)

Data Plan: Annual, provided by Decagon Devices with 120 global partners, GSM service

Server Location: Decagon Devices; Pullman, Washington

Data Security: SSL/TLS encrypted data transfer; a unique Device ID and password (provided with each logger) are necessary for accessing data from the server.

Cellular Frequencies

Quad-band (850/900/1800/1900 MHz) GSM/GPRS for use worldwide.

Comparisons

Data LoggerPortsMemoryBatt. LifeCaseCompatibility w/SensorsWireless Options
Em5B 5 49 KB (18,000 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, 10HS, EC-10, EC-20, temperature, precipitation None
Em50 5 1 MB (36,000 scans) 1 - 3 years Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed, drain gauge None
Em50R 5 1 MB (36,000 scans) 6 months - 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed 900 MHz, 922 MHz, 2.4 GHz
em50g 5 1 MB (36,000 scans) 6 months - 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed GSM
Em5 (discontinued) 5 47 KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation None
Em5R (discontinued) 5 47 KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation 900 MHz

Support

Video

  • Video: Setting up the Em50G
  • Video Index

Manuals

  • Em50G Quickstart Guide
  • Manual Em50/ Em50R/ Em50G

Application Notes

  • DataTrac 3 Installation

Software & Downloads

  • DataTrac 3 Installation
  • Decagon USB Cable Adapter Driver (version 6.5)
  • ECH2O Utility (version 1.66)
  • Em50 Firmware Updater (version 2.12)

Information Sheet

  • EM50G Information Sheet

Request Support

Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158

Education

Virtual Seminar

  • November 9, 2010: Virtual Seminar: Strawberries: The Effects of Modifying Irrigation Methods for Transplant Establishment

Sign up for News & Updates

Please fill out the information below

Related Products or Services

  • Em50 Digital/Analog Data Logger
  • Soil Moisture Sensors
  • DataTrac 3
  • Environmental Sensors
2365 NE Hopkins Court
Pullman, WA 99163 - USA
1-800-755-2751 / Int'l: 509-332-2756
© 2013 Decagon Devices, Inc. - All Rights Reserved