Many a researcher has looked over a soil moisture data set and thought, "I wish I had temperature data with this..."
The 5TM delivers temperature, measured by an onboard thermistor, along with accurate volumetric water content.
The 5TM determines volumetric water content (VWC) by measuring the dielectric constant of the soil (or other media) using capacitance/frequency domain technology. Signal filtering minimizes salinity and textural effects, making the 5TM accurate in most soils and soilless media. Factory calibrations are included for mineral soils, potting soils, rockwool, and perlite.
The 5TM's small size makes it easy to install--perfect for in field installations. This robust probe can be pushed directly into undisturbed soil to ensure good accuracy. Its compact design makes it useful not only in the field, but also in labs or greenhouses.
Get straight to the data with an Em50-series data logger. Just install the 5TM, plug it into the Em50, set the clock and measurement intervals, and start logging data. No programming required.
Want to Use a Different Logger? No Problem!
The 5TM comes standard with both serial and SDI-12 communication options, meaning easy integration with systems manufactured by other companies (such as Campbell Scientific).
If you want to measure volumetric water content, AND
Part number 40490 (Stereo), 40491 (Pigtail), 40492 (Custom)
| Accuracy |
Apparent Dielectric Permittivity (εa): ± 1 εa from 1 - 40 (soil range); ± 15% from 40 - 80 Soil Volumetric Water Content (VWC):
|
|
|---|---|---|
| Resolution |
εa: 0.1 εa from 1-20, < 0.75 εa from 20-80 VWC: 0.0008 m3/m3 (0.08% VWC) from 0 to 50% VWC Temperature: 0.1°C |
|
| RANGE |
|
|
| Dimensions | 10 cm x 3.2 cm x 0.7cm | |
| Cable Length | 5 m standard, custom cable lengths available upon request | |
| Measurement Time | 150 ms (milliseconds) | |
| Power | 3.6 - 15 VDC, 0.3 mA quiescent, 10 mA during 150 ms measurement | |
| Output | RS232 or SDI-12 | |
| Connector Types | 3.5mm "stereo" plug, or stripped and tinned lead wires (3) | |
| Data Logger Compatibility (not exclusive) |
Decagon: Em50 series loggers, ProCheck Campbell Scientific: Any logger with serial I/O (CR10X, CR850, CR1000, CR3000, etc.) Other: Any data acquisition system capable of 3.6-15V excitation and serial or SDI-12 communication |
|
| Warranty | One year, parts and labor |
| ANALOG SENSORS | DIGITAL SENSORS | |||||
| SENSOR | EC-5 | 10HS | 5TM | 5TE | GS3 | MPS-2 |
|---|---|---|---|---|---|---|
| MEASURES | volumetric water content, dielectric permittivity | volumetric water content, dielectric permittivity | volumetric water content, dielectric permittivity, temperature |
volumetric water content, dielectric permittivity, temperature, electrical conductivity | volumetric water content, dielectric permittivity, temperature, electrical conductivity | water potential, temperature |
| VOLUME OF INFLUENCE | 0.3 L | 1 L | 0.3 L | 0.3 L | 0.3 L | N/A |
| DATA LOGGER COMPATIBILITY | Em5b, Em50, Em50R, Em50G, ProCheck, ECH2O Check, Campbell Scientific* | Em5b, Em50, Em50R, Em50G, ProCheck, ECH2O Check, Campbell Scientific* |
Em50, Em50R, Em50G, ProCheck, Campbell Scientific*, SDI-12 capable |
Em50, Em50R, Em50G, ProCheck, SDI-12 capable |
Em50, Em50R, Em50G, ProCheck, SDI-12 capable |
Em50, Em50R, Em50G, ProCheck, SDI-12 capable |
| MEASUREMENT RANGE | 0 to 100% VWC | 0 to 53% VWC |
0 to 100% VWC -40 to 50°C |
0 to 100% VWC -40 to 50°C 0 to 23 dS/m |
0 to 100% VWC -40 to 50°C 0 to 23 dS/m |
-10 to -500 kPa (pF 2 - pF 3.71) -40 to 50°C |
| BEST IF | VWC is all that you need. You're establishing a large sensor network. |
You want a large volume of influence. |
You have high temperature variability in your soils. You need to monitor soil temperature for biological activities. You want to use SDI-12. |
You are managing salts in your system. You want to use SDI-12. |
You are measuring water content of soilless substrates. You need high accuracy EC. |
You want to compare soil moisture at different research sites. You want to measure water potential. |
| BUT NOT IF | You cannot apply a regulated voltage (only applies to non-Decagon data loggers). | You are measuring in nursery pots. You are installing in rocky soil. |
N/A | You want to monitor soiless substrates or potting soils. | You are doing downhole installations. | You want to monitor soils at or near saturation. |
Note: ECH2O sensors are “plug and read” on Decagon data loggers. You do not need to program any of this information (or ANY information) into a Decagon logger.
| SENSOR | CAMPBELL COMPATIBILITY | OTHER LOGGERS | OUTPUT | VOLTAGE REQUIREMENTS |
|---|---|---|---|---|
| EC-5 | CR10X, 21X, 23X, CR1000, CR3000, etc. | Any data acquisition system capable of switched 2.5 to 3.6 V excitation and single ended voltage measurement at 12 bit or better resolution. (Note: some people take their chances with resolution as low as 3 bits, but resolution lower than 10 bits will leave the data quite choppy). | Voltage, correlated linearly (soil) or polynomially (growing media) with VWC | 2.5-3.6 V |
| 10HS | CR10X, 21X, 23X, CR1000, CR3000, etc. | Any data acquisition system capable of 3-15 VDC excitation and single ended voltage measurement at 12 bit or better resolution. | Voltage correlated with VWC, independent of excitation | 3-15 V |
| 5TE | Any logger with serial I/O (CR10X, CR850, CR1000, CR3000, etc.) | Ask a Decagon representative for an integrator’s guide to interfacing the 5TE | Digital ASCIII stream or SDI-12 | 3.6-15 V |
| 5TM | Any logger with serial I/O (CR10X, CR850, CR1000, CR3000, etc.) |
Ask a Decagon representative for an integrators guide to interfacing the 5TM | Digital ASCII Stream or SDI-12 | 3.6-15 V |
| GS3 | Any logger with serial I/O (CR10X, CR850, CR1000, CR3000, etc.) |
Ask a Decagon representative for an integrators guide to interfacing the GS3 | Digital ASCII Stream or SDI-12 | 3.6-15 V |
| MPS-2 | Any logger with serial I/O (CR10X, CR850, CR1000, CR3000, etc.) |
Ask a Decagon represenative for an integrators guide to interfacing the MPS-2 | Digital ASCII Stream or SDI-12 | 3.6-15 V |
For use with deep installation of the ECH2O probes. Includes a regular and sand auger (2.75" [7 cm] diameter), two 2' (0.6 m) extension rods, a standard rubber handle, and a ratchet handle.
Give your cables a higher level of protection from the elements and rodents. Also organizes your cables as you run them to your datalogger.
Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158