Skip to the content Skip to the navigation Accessibility information
Decagon Devices
Login|Register| Contact us
US: 1.800.755.2751
International: +1.509.332.2756
  • Home
  • Products
    • Water Activity
    • Environmental Instruments
    • Sensors
    • Data Loggers and Collectors
    • Environmental Monitoring Systems
    • Lysimeters and Infiltrometers
  • Services
    • Thermal Properties Testing
    • Soil Moisture Release Curve Construction
    • Campbell Scientific Data Logger Programming
    • Soil Moisture Sensor Custom Calibration
  • Support
  • News & Events
  • Where to buy
  • About Us
    • About Us
    • Contact Us
    • Sister Companies
    • Employment
    • GA Harris Fellowship
    • People
  • Education
  • Forums
    • Soil Moisture
    • Data Loggers and Data Management
    • Canopy Measurements
    • Soil Water Potential
    • Lysimetry and Hydrology
    • Clarke Topp Twenty Questions
    • Best Practices of Soil Moisture Measurements Virtual Seminar Questions
    • Thermal Properties
    • Methods of Sampling and Analyzing Soil Pore Solution Virtual Seminar Questions
    • Basic Principles of Radiation Measurement to Predict ET, Climate Change, Photosynthesis and Crop Yield
Products
  • Water Activity
  • Environmental Instruments
  • Sensors
    • Soil Moisture Sensors
      • EC-5 Soil Moisture
      • 10HS Soil Moisture
      • 5TM Soil Moisture
      • 5TE Soil Moisture
      • GS3 Soil Moisture, Temperature and EC
      • MAS-1 4-20 milliamp water content sensor
    • Water Potential Sensors
    • Environmental Sensors
  • Data Loggers and Collectors
  • Environmental Monitoring Systems
  • Lysimeters and Infiltrometers
Request a
Quote
No Obligation
Subscribe to
newsletter
Tips, tricks, and Scholarships
Email to
a Friend
Send this page link to a friend

Soil Moisture Sensors

  • Measurements:
    • Dielectric Permittivity,
    • Electrical Conductivity (EC),
    • Temperature,
    • Volumetric Water Content
  • Applications:
    • Greenhouse Management,
    • Irrigation Scheduling,
    • Water Balance Studies
  • Overview
  • Comparisons
  • Accessories
  • Support
  • Education

 

Soil moisture is highly variable. Accuracy from a single site isn't enough to run an experiment. To make good soil moisture measurements, you need research quality probes and you need a lot of them.

Decagon's soil moisture sensors are research grade probes at a price that lets you completely characterize your site.

Plug-and-log with the Em50 line of data loggers or integrate into other logger systems (including Campbell Scientific).

Watch our five minute video on how to install soil moisture sensors

Soil-Moisture-Sensors-PSub-1496-x-2250.jpg

Comparisons

 

AnalogDigitalAnalog
Sensor EC-5 10HS 5TM 5TE MPS-1
Measures volumetric water content volumetric water content, dielectric permittivity volumetric water content, temperature volumetric water content, dielectric permittivity, temperature, electrical conductivity water potential
Volume of Influence 0.3 L 1 L 0.3 L 0.3 L N/A
Data Logger Compatibility Em5b, Em50, Em50R, ProCheck, ECH2O Check, Campbell Scientific* Em5b, Em50, Em50R, ProCheck, ECH2O Check, Campbell Scientific* Em50, Em50R, ProCheck Em50, Em50R, ProCheck, Campbell Scientific* Em5b, Em50, Em50R, ProCheck, Campbell Scientific*
Range 0-100% VWC 0-53% VWC 0-100% VWC 40-50°C 0-100% VWC 40-50°C 0-23dS/m -10 to -500 kPa(pF 2 to pF 3.71)
Best If VWC is all you need.

You're establishing a large sensor network
you want large volume of influence you have high temperature variability in your soils.

you are monitoring shallow or desert soils where data must be corrected for temperature effects.
you are managing salts in your system.

you want to use SDI-12
you want to compare soil moisture at different research sites.

you want to determine water available for plant growth.

you are monitoring deficit irrigation.
But Not If you cannot apply a regulated voltage (only applies to non-Decagon data loggers). you are measuring in nursery pots.

you are installing in rocky soil.
 N/A you want to monitor soiless substrates or potting soils. you want to monitor soils at or near field capacity.

Accessories

Auger-Kit.JPG

Auger Kit

For use with deep installation of the ECH2O probes. Includes a regular and sand auger (2.75" [7 cm] diameter), two 2' (0.6 m) extension rods, a standard rubber handle, and a ratchet handle.

cable-armor.jpg

Cable Armor

Give your cables a higher level of protection from the elements and rodents. Also organizes your cables as you run them to your datalogger.

Installation-Tool.jpg

Installation Kit

Install sensor into augered hole or a sidewall. Use the insertion tool to create a pilot hole before inserting the sensor in hard or rocky soils.

Splice-Kit.png

Splice Kit

Repair damaged cables in the field with few tools and less time.

Support

Software & Downloads

  • multiplexing the 5TE/5TM using the CR1000 data logger
  • using the 5TE/5TM sensors with the CSI CR1000
  • For using the 5TE/5TM with the CR10X data logger
  • Multiplexing the 5TE/5TM using the CR10X data logger
  • EchoCSI.zip - SCWin (ShortCut)
  • SDI12 Example Program for the 5TM
  • SDI12 Example Program for the 5TE

Application Notes

  • 10HS Volume of Sensitivity
  • Calibrating ECH2O Soil Moisture Sensors
  • Calibration Equations for the ECH2O EC-5, ECH2O-TE and 5TE Sensors
  • Calibration and Evaluation of an Improved Low-Cost Soil Moisture Sensor
  • Correcting temperature sensitivity of ECH2O soil moisture sensors
  • EC-5 Volume of Sensitivity
  • ECH2O Dielectric Probes vs. Time Domain Reflectometers (TDR)
  • Electrical Conductivity of Soil as a Predictor of Plant Response
  • FAQ: Soil Moisture Probes and Accessoris
  • Measuring Water Content in Soil-less Media Uing ECH2O Probes
  • Modeling Available Soil Moisture
  • Using SCWin (Short Cut) to read EC-5, -10, and -20, MPS-1, and 10HS Sensors with Campbell Scientific
  • Using the CSI AM416 or AM16/32 Multiplexer with EC-5, -10, and -20 Soil Moisture Sensors
  • Wire Splicing and Sealing Technique for Soil Moisture Sensors

Troubleshooting Articles

  • Calibrating ECH2O Soil Moisture Sensors
  • Calibration Equations for the ECH2O EC-5, ECH2O-TE and 5TE Sensors
  • Correcting temperature sensitivity of ECH2O soil moisture sensors
  • FAQ: Soil Moisture Probes and Accessoris
  • Newsletter-Surprise! The Probe is Right
  • Using the CSI AM416 or AM16/32 Multiplexer with EC-5, -10, and -20 Soil Moisture Sensors

How-To Articles

  • Calibrating ECH2O Soil Moisture Sensors
  • Calibration Equations for the ECH2O EC-5, ECH2O-TE and 5TE Sensors
  • Newsletter-Six Installation Tips
  • Newsletter-Using soil water sensors for efficient irrigation in greenhouses
  • Using SCWin (Short Cut) to read EC-5, -10, and -20, MPS-1, and 10HS Sensors with Campbell Scientific
  • Using the CSI AM416 or AM16/32 Multiplexer with EC-5, -10, and -20 Soil Moisture Sensors
  • Wire Splicing and Sealing Technique for Soil Moisture Sensors

Manuals

  • Manual 5TE
  • Manual 5TM
  • Manual-10HS
  • Manual-EC-5

Information Sheet

  • 5TE 5TM Integrator's Guides for Serial and SDI-12 Communication
  • Meet your Decagon Soil Moisture Sensor

Request Support

Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158

Or send us an information request:

Education

Virtual Seminar

  • September 11, 2009: Virtual Seminar: Using Decagon Moisture Sensors for the Precision Irrigation of Soilless Substrates
  • November 9, 2010: Virtual Seminar: Strawberries: The Effects of Modifying Irrigation Methods for Transplant Establishment
  • July 27, 2010: Virtual Seminar: New Vadose Zone Monitoring Technology
  • October 14, 2009: Virtual Seminar: Soil Moisture Sensors for Irrigation Control and Drought Stress Research of Greenhouse and Nursery Crops
  • February 17, 2010: Virtual Seminar: Quantification of Resource Capture Efficiency for Cultivar Improvement
  • March 25, 2010: Virtual Seminar: Soil Moisture Measurement Methods and Field Applications
  • April 22, 2010: Virtual Seminar: Why Does my Soil Moisture Sensor Read Negative? How Accuracy of Dielectric Soil Moisture Sensors can Change your Data Set
  • July 8, 2010: Virtual Seminar: Solute Signatures: Monitoring and Interpreting Salt and Nitrate Levels in the Root-Zone
  • Virtual Seminar Index
  • October 26, 2011: Free Virtual Seminar: Best Practices for SDI-12 Sensor Networks

Newsletters

  • Canopy News 2007
  • Gauging the Green-2007
  • Geoenvironmental Engineering Newsletter-2007
  • Soils News-2002
  • Soils Notes-2003
  • Soils News-2004
  • Soils News-2005
  • Soils News-2006
  • Soils News-2007
  • Soils News-2008
  • Soils News-2009

Newsletter Articles

  • November 5, 2007: Electrical Conductivity of Soil as a Predictor of Plant Response
  • Newsletter-Capacitance and TDR Probe: Differences
  • Newsletter-Effect of Soil Moisture on Ground Hardness for Snowmobile Pass-by Noise Testing
  • Newsletter-Grazing Impacts Subalpine Hydrology
  • Newsletter-Improving ECH2O Field Performance
  • January 25, 2007: Newsletter-Measuring Water Content of Compost
  • March 31, 2009: Newsletter-Sampling Moisture in the Soil Profile
  • March 31, 2009: Newsletter-Six Installation Tips
  • March 31, 2009: Newsletter-Surprise! The Probe is Right
  • Newsletter-Testing of ECH2O Soil Moisture Probes in Oasis Agriculture of Oman
  • Newsletter-The Wilting Coefficient and Its Relation to Soil Water Content and Potential
  • January 25, 2007: Newsletter-Using Soil Moisture Sensors in Environmental Sensing Networks
  • Newsletter-Using soil water sensors for efficient irrigation in greenhouses
  • September 7, 2007: Newsletter-Wireless Nursery and Greenhouse Management

List of Cited Publications

  • Cited Publications - ECH2O 2007
  • Cited Publications - ECH2O 2008-2010
  • Cited Publications - ECH2O 2006
  • Cited Publications - ECH2O 2005
  • Cited Publications - ECH2O 2002 -2004

Video

  • Video: Custom Soil Calibration for VWC Sensors
  • Video: ECH2O Sensor Installation Demo
  • Video: Splicing the End of a Cut Sensor Wire
  • Video Index

Sign up for News & Updates

Please fill out the information below

Related Products or Services

  • DataTrac 3
  • Water Potential Sensors
  • Em50G Wireless Cellular Data Logger
  • Environmental Sensors
EC5 Cutout

EC-5 Soil Moisture, small area of influence

Our lowest-cost soil moisture sensor. Measures Volumetric Water Content only. Just 5 cm long with a 0.3 L measurement volume, this handy little sensor is easy to install in the field and can also be used in nursery pots. » Learn more

10HS-cutout.jpg

10HS Soil Moisture, large area of influence

Measure volumetric water content in a larger soil sample. The 10HS has a 1 liter volume of influence. High frequency oscillation and patented signal filtering deliver excellent accuracy and minimal textural effects; analog output makes it easy to use with other data loggers including Campbell Scientific. This 10 cm long probe is best installed in the field. » Learn more

5TM.jpg

5TM Soil Moisture and Temperature

Get temperature data integrated with your soil moisture data—at the same location and over the same measurement intervals. Ideal for adding temperature to each node in your network. Serial and SDI-12 communication give lots of options for integrating into systems run by other data loggers (including Campbell Scientific). » Learn more

5TEtrans.png

5TE Soil Moisture, Temperature and EC

Our full-featured soil moisture sensor. Measures volumetric water content, temperature, and electrical conductivity in soil. This three-pronged, 5 cm long sensor is for use in soil only. High frequency oscillation and patented signal filtering deliver excellent accuracy with minimal textural effects. Serial or SDI-12 communication give lots of options for integrating into systems run by other data loggers (including Campbell Scientific). » Learn more

SENSOR-square.jpg

GS3 Soil Moisture, Temperature and EC

A moisture sensor for soilless substrates such as rockwool, potting soil, peat, and perlite. The GS3 measures water content, temperature,and bulk electrical conductivity. Stainless steel needles have an extended surface area to optimize EC measurements and minimize substrate disturbance during insertion. Serial or SDI-12 communication; plug and log with Decagon data loggers or integrate with other data loggers (including Campbell Scientific). » Learn more

MAS-1.png

MAS-1 4-20 milliamp water content sensor

The MAS-1 4-20 milliamp sensor accurately measures water content with a standard 4-20 milliamp output. This sensor is best for industrial systems or systems where a sensor with 250 feet of cable or greater is required. » Learn more

2365 NE Hopkins Court
Pullman, WA 99163 - USA
1-800-755-2751 / Int'l: 509-332-2756
© 2012 Decagon Devices, Inc. - All Rights Reserved