Skip to the content Skip to the navigation Accessibility information
Decagon Devices
Login|Register| Contact us
US: 1.800.755.2751
International: +1.509.332.2756
  • Home
  • Products
    • Water Activity
    • Environmental Instruments
    • Sensors
    • Data Loggers and Collectors
    • Environmental Monitoring Systems
    • Lysimeters and Infiltrometers
  • Services
    • Thermal Properties Testing
    • Soil Moisture Release Curve Construction
    • Campbell Scientific Data Logger Programming
    • Soil Moisture Sensor Custom Calibration
  • Support
  • News & Events
  • Where to buy
  • About Us
    • About Us
    • Contact Us
    • Sister Companies
    • Employment
    • GA Harris Fellowship
    • People
  • Education
  • Forums
    • Soil Moisture
    • Data Loggers and Data Management
    • Canopy Measurements
    • Soil Water Potential
    • Lysimetry and Hydrology
    • Clarke Topp Twenty Questions
    • Best Practices of Soil Moisture Measurements Virtual Seminar Questions
    • Thermal Properties
    • Methods of Sampling and Analyzing Soil Pore Solution Virtual Seminar Questions
    • Basic Principles of Radiation Measurement to Predict ET, Climate Change, Photosynthesis and Crop Yield
    • Lysimetry Basics: Peering in to the Black Box Virtual Seminar Questions
Products
  • Water Activity
  • Environmental Instruments
  • Sensors
  • Data Loggers and Collectors
    • Continuous Data Loggers
      • Em50 Digital/Analog Data Logger
      • Em50G Wireless Cellular Data Logger
      • Em50R Wireless Radio Data Logger
      • Em5b Analog Data Logger
    • Instantaneous Data Collectors
    • Data Management Software
    • Rugged Field Computer
  • Environmental Monitoring Systems
  • Lysimeters and Infiltrometers
Request a
Quote
No Obligation
Subscribe to
newsletter
Tips, tricks, and Scholarships
Email to
a Friend
Send this page link to a friend

Continuous Data Loggers

  • Applications:
    • Greenhouse Management,
    • Hydrology,
    • Irrigation Scheduling,
    • Microbial Ecology,
    • Water Balance Studies,
    • Watershed Characterization,
    • Wireless Sensor Networks
  • Overview
  • Comparisons
  • Accessories
  • Support
  • Education

Looking for a logger to power your sensors and read and store the measurement data? The Em50 series simplifies data logging because it's:

  • Pre-programmed. No user programming necessary.
  • Powered by 5 AA batteries. No external power source required.
  • Weatherproof. No extra enclosure needed.

Just plug in any sensor Decagon sells, set your sensor type and measurement intervals using drop down menus, and start logging data.

Continuous-Data-Loggers-PS-HERO.jpg Em50.jpg em50g-cutout1.jpg Em5b-DROP.jpg

Comparisons

 

Data LoggerPortsMemoryBatt. LifeCaseCompatibility w/SensorsWireless Options
Em5B 5 49KB (18,000 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, 10HS, EC-10, EC-20, temperature, precipitation None
Em50 5 1MB (36,000 scans) 1-3 years Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed, drain gauge None
Em50R 5 1MB (36,000 scans) 6 months- 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed 900 MHz, 922 MHz, 2.4 GHz
Em50G 5 1 MB (36,000 scans) 6 months- 1 year Weatherproof, UV- and impact-resistant IP55, NEMA 3R EC-5, 10HS, 5TE, EC-TM, MPS-1, PAR, LWS, Temp, Temp/RH, precipitation, wind speed GSM
Em5 (discontinued) 5 47KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation None
Em5R (discontinued) 5 47KB (3,400 scans) Several months Impact-resistant IP52, NEMA 3R EC-5, EC-10, EC-20, temperature, precipitation 900 MHz

Accessories

DataStation-HERO1.jpg

DataStation

Collects data wirelessly from up to 80 data loggers within radio range (typically 1-3 miles). Stores 36,000 packets of data.

RM1-HERO1.jpg

Rm-1

The Rm-1 is a radio modem used for real-time connection to the Em50R data loggers. The RM-1 can also be used as a repeater in the wireless system. Use the Rm-1 with to change the logger name, logger date/time, sampling interval, and ports sensors assignments. You can also use it to download logged data all remotely from the convenience of your computer.

Support

Video

  • Video: Setting up the Em50G
  • Video Index

Manuals

  • Em50G Quickstart Guide
  • Manual Em50/ Em50R/ Em50G
  • Manual Em5b

Application Notes

  • DataTrac 3 Installation

Software & Downloads

  • DataTrac 3 Installation
  • Decagon USB Cable Adaptor Driver (version 6.5)
  • ECH2O Utility (version 1.64)
  • Em50 Firmware Updater (version 2.10)
  • Em50G Downloader

Information Sheet

  • EM50G Information Sheet

Request Support

Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158

Or send us an information request:

Education

Virtual Seminar

  • November 9, 2010: Virtual Seminar: Strawberries: The Effects of Modifying Irrigation Methods for Transplant Establishment

Newsletters

  • Canopy News 2005
  • Soils News-2004

Sign up for News & Updates

Please fill out the information below

Related Products or Services

  • DataTrac 3
  • Sensors
Em50.jpg

Em50 Digital/Analog Data Logger

This self-contained logger will power and read any Decagon sensor. Runs for one to three years (depending on measurement intervals) on 5 AA batteries. Stores over 36,000 scans in 1 MB memory. RS-232 serial or USB connection to download data. Download software included. » Learn more

em50g-cutout1.jpg

Em50G Wireless Cellular Data Logger

Em50 data logger with cellular connectivity. Check on your data logger and view your data from virtually anywhere in the world. Wireless cell modem automatically sends data to an internet server four times a day. One year data plan included in initial purchase; after that, an annual fee is required. » Learn more

Em50R-Wireless-Radio-Logger.JPG

Em50R Wireless Radio Data Logger

Em50 data logger with radio connectivity. Transmit data wirelessly from the Em50R to a computer over intermediate (1-3 mile) distances. Can connect multiple logger nodes to a single central data station. Limited range, but no annual costs for data plan subscription. » Learn more

Em5b-DROP.jpg

Em5b Analog Data Logger

Low cost, limited use five-channel mini-logger. Powers and reads analog sensors (EC-5 and 10HS soil moisture sensor, rain gauges, ECT temperature sensor). Best for inexpensively adding spatial resolution to soil moisture studies. » Learn more

2365 NE Hopkins Court
Pullman, WA 99163 - USA
1-800-755-2751 / Int'l: 509-332-2756
© 2012 Decagon Devices, Inc. - All Rights Reserved